Products: Tecnis Symfony Extended Depth of Focus Model ZXR

Web background

TECNIS SYMFONY® IOL

SEAMLESS BRILLIANCE

The TECNIS Symfony® IOL mitigates the effects of presbyopia so you can empower your patients to see clearly across the full range of vision.

Recommended IOL Insertion:

  • UNFOLDER® Platinum 1 Series Delivery System
  • UNFOLDER® Emerald Delivery System
  • One Series Delivery System
Tecnis Symfony

SHARPEST CONTINUOUS VISION

Delivering excellent uncorrected visual acuity (VA) at all distances,1 the TECNIS Symfony® IOL allows your patients to see clearly across a full range of vision.

Defocus Curve1

6-Month Data, Bilaterally Implanted Subjects

  • Sustained 20/25 or better mean VA through 1.5 D
  • Sustained 20/40 or better mean VA through 2.5 D
  • Increase of 1.0 D range of vision throughout the defocus curve

Rather than splitting light into distinct focal points, the TECNIS Symfony® IOL elongates focus, resulting in an increased depth of field. This empowers you to deliver a full range of continuous vision while maintaining high image contrast.

Monocular Contrast Sensitivity at 6 Months1

Mesopic without Glare

ENHANCED FUNCTIONALITY

Deliver the visual quality that allows your patients with and without astigmatism to see clearly in any lighting condition.

  • High-quality distance vision in the presence of astigmatism2
  • Pupil-independent performance enables optimal performance in any lighting condition1
  • Low overall spectacle wear1

The TECNIS Symfony® IOL delivers 20/20 or better vision through 1.5 D of astigmatism.1

85% of patients wear glasses none or a little bit of the time.1

By combining a unique diffractive pattern with achromatic technology, the TECNIS Symfony® IOL delivers outstanding visual acuity over a continuous range of distances while maintaining high contrast performance.

  • Proprietary relief profile elongates focus1
  • Proprietary achromatic technology corrects chromatic aberration and enhances image contrast1

Degree of Difficulty with Visual Symptoms1

Percentage of Eyes, Non-Directed Reports, 6 Months Postoperative

Low incidence of visual symptoms, including halos, glare and starbursts1

LONG-TERM SUSTAINABILITY

Unlike another leading IOL, TECNIS® IOL material is not associated with glistenings,3-7which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.4-8

FOOTNOTES

*Value theoretically derived for a typical 22.0 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

REFERENCES

  1. TECNIS Symfony® Extended Range of Vision IOLs DFU. Santa Ana, Calif. Abbott Medical Optics Inc.
  2. Data on File. Abbott Medical Optics Inc. 2016.
  3. Data on File. Abbott Medical Optics Inc. 2013.
  4. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010 Dec;36(12):2056-2060.
  5. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001; 27(5):728-733.
  6. Colin J, et al. Incidence of glistenings with the latest generation of yellow- tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012; 38:(7)1140-1146.
  7. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001; 27(10):1611-1614.
  8. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-304.
  9. Calculated based on Holladay I formula: Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24.

EXPLORE