TECNIS® MULTIFOCAL IOL +4.0 D
OUTSTANDING, FULL-RANGE VISION TAILORED FOR NEAR DISTANCES
Engineered to help you meet unique visual demands, TECNIS®Multifocal IOLs allow you to deliver tailored clarity that suits your patients’ daily needs. The TECNIS® Multifocal IOL +4.0 D delivers a full range of the sharpest vision tailored for near distances.
Recommended IOL Insertion:
- UNFOLDER® Platinum 1 Series Delivery System

The TECNIS® Multifocal IOL +4.0 D is designed with your patients in mind. Optimized for those favoring near-vision activities like reading and knitting, it delivers tailored clarity at a theoretical reading distance of 33 cm.

SHARPEST VISION ACROSS ALL DISTANCES
The TECNIS® Multifocal Family of 1-Piece IOLs features the only multifocal lenses capable of providing a full range of high-quality vision (20/25 or better),1,2 tailored for each patient’s lifestyle.
- The sharpest vision across near, intermediate and distance vision1,2
- Optimized for a theoretical reading distance of 33 cm with the +4.0 D lens
When compared to other leading multifocal IOLs, TECNIS® Multifocal IOLs provide:
- Up to 4x higher image contrast at near distance in low light (5 mm pupil)3
- 2x higher image contrast at near distance in normal light (3 mm pupil)3
ENHANCED FUNCTIONALITY
Give your patients a lens designed for real-world performance. The TECNIS® Multifocal IOL +4.0 D delivers increased, tailored spectacle independence.
How Often Do You Wear Glasses?*1,2

+4.0 D (purple) data are historical from a separate clinical study using the same test methodology.
Degree of Difficulty** With Night Vision1,2

+4.0 D (purple) data are historical from a separate clinical study using the same test methodology.
LONG-TERM SUSTAINABILITY
Unlike another leading IOL, TECNIS® IOL material is not associated with glistenings,4-8
which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.5-9
FOOTNOTES
- *The questionnaire was not determined to be a psychometrically valid assessment of the concept of spectacle independence.
- **On a scale of 1-7, with glasses as needed
- †Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.
- ‡Derived from clinical evaluation results of the TECNIS® 1-Piece Platform.
REFERENCES
- TECNIS® Multifocal 1-Piece IOL DFU, Models ZKB00 and ZLB00. Santa Ana, Calif. Abbott Medical Optics Inc.
- TECNIS® Multifocal 1-Piece IOL DFU, Model ZMB00. Santa Ana, Calif. Abbott Medical Optics Inc.
- Data on File. Abbott Medical Optics Inc. 2015.
- Data on File. Abbott Medical Optics Inc. 2013.
- Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060.
- Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733.
- Colin J, et al. Incidence of glistenings with the latest generation of yellow- tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146.
- Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614.
- Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304.
- Calculated based on Holladay I formula: Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruis RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24.